What happened

The National Federation of Roofing Contractors (NFRC) has released new guidance on waterproofing details at rooflights and roof windows on flat roofs. The document, titled GN87: Waterproofing interfaces at rooflights and roof windows on flat roofs, was created in partnership with three other industry groups: the Liquid Roofing and Waterproofing Association (LRWA), the Rooflight Association (RA), and the Single Ply Roofing Association (SPRA). According to Roofing Today, the aim is to help contractors, designers and specifiers correctly detail these junctions and avoid common defects.

The guidance outlines how laps in membrane and added reinforcement at rooflight locations can result in uneven substrate surfaces beneath rooflight frames. This can lead to issues with seals, fixings, and drainage performance if not addressed at the design and pre-installation stages. The document goes on to explain that there is no single detail that suits all circumstances, given the variety of rooflight and waterproofing systems used across the flat roofing sector.

The background

Industry organisations report that junctions between flat roof membranes and rooflight upstands are frequent sources of leaks and defects, often arising from poor installation, incompatible components, or a lack of coordination between trades. The new GN87 guidance responds to this by bringing together expertise from roofing and rooflight sectors to provide practical advice based on experience.

The document details the need for coordination between the design of the waterproofing system and the rooflight setting before work begins. This includes agreeing correct dimensions for upstand heights, the use and positioning of proprietary kerbs, insulation detailing, and management of membrane laps and flashings. The guidance recognises that different manufacturers have their own requirements and recommends resolving conflicting details at the design stage, before materials are ordered and installed.

The document also sets out that contractors should inspect and photograph the waterproofing once finished, but before the rooflight is installed. It states that finished upstand dimensions should always be checked. The guidance says required membrane layers should never be removed in an attempt to create a flatter surface, as this can weaken the system. It also instructs that rooflights should not be fixed forcibly onto uneven upstands using overtightened fixings, as this can compromise the effectiveness of seals and drainage.

What people are saying

According to Roofing Today, the four industry bodies involved describe the document as a collaborative effort designed to reflect the practical realities faced by installers and designers. They say the central message is that achieving effective waterproofing at rooflight interfaces depends on early coordination between the specialist trades and adherence to manufacturer guidance.

The NFRC and its partners state that the guidance brings together sector experience to drive better communication between specification, manufacturing, and on-site installation teams. They highlight that with greater cooperation, longstanding problems such as leakage and poor drainage performance at rooflight junctions can be addressed more consistently.

The associations say that the new guidance reflects the sector’s response to recurring defects at these junctions and that it is intended as a practical tool for both new build and refurbishment flat roofing projects.

What happens next

The new guidance document GN87 is now publicly available from the NFRC and the partner associations. Designers, specifiers, and contractors working on flat roofs with rooflights or roof windows are encouraged to consult the guidance at the early design and planning stages of projects.

The industry bodies advise that the guidance should be used alongside manufacturer literature and project-specific requirements to develop site details that ensure performance and durability. They expect the adoption of the guidance to lead to better on-site practice, reduce avoidable defects, and extend the service lives of both waterproofing systems and rooflights.

The organisations involved will monitor feedback from practitioners and may update the guidance in future editions to reflect new products, common site issues, or regulatory changes as appropriate.